A summary
Y series for general use mouse cage self-cooling sealed three asynchronous motor, protection grade for IP44.
Y series motor in the following conditions ensure rated operating.
1 and environmental temperature does not exceed 40 ° c. 2 and no more than 1000 meters altitude. 3 and power frequency 50hz, voltage 380 volts, Working for continuous (SI), Insulation grade B, Wiring method. According to the nameplate
Second, the motor installed
(a) before installation
1, before installation check carefully motor ring transportation and undamage, remove dirt on the motor shaft and the antirust layer.
2 check motor nameplates, all data on whether accord with the requirement.
3 and check whether parts, fasteners without loosing fully equipped with the hand, or turn out to be flexible and motor rotor shaft.
4, 500 volts with ZhaoOuBiao measuring insulation resistance of stator windings shall not less than 2 trillion ohms for 380-volt ac, otherwise the stator winding of coping with dry processing, drying temperature of 120 degrees shall not exceed.
(2)
1, the motor installed shall ensure its good ventilation cooling conditions. Not for the hot sun rain.
2, the motor installed should be properly grounded! Junction box with grounding and marks. When necessary, can use of motor or lugs bolt grounding.
3, motor terminal box on the board, with six changing U1 respectively, V1, U2, V2 W1 and W2, mark. U1, U2, V1 and V2 W2, respectively, W1 three groups of windings, end. According to the provisions of the plate pick up into the train or Y.
4 and when the power supply sequence in changing U1 symbol of ABC, V1, W1 relative, timely, motor shaft stretched from the as clockwise. When installing no-load motor can be tested steering, such as not in conformity with the load, replace the power supply in order to adjust the motor.
Five, the motor installed coupling, pulley (fan) or other parts of rotating impeller, should avoid using hammering forced into the assembly. Knock May adopt the cold pressing bed or will turn into the motor shaft parts of heating. Otherwise, will cause damage or motor bearing abnormal voice can't even use normally.
Third, the motor running
1 and power frequency deviation and rated voltage or exceed 1% of the deviation of more than 5% and ratings, motor can ensure continuous rated power output.
2, motor doesn't allow overload current exceeds ratings continuous operation (.).
3 and when operating electromotor should not abnormal noise or vibration. Bearing temperature should be no more than 95 degrees. After half a year in operation, motor bearing oiling response.
Four, motor maintenance and storage
1 and using environment should always keep dry and clean. Motor Menorca should not receive st, fiber etc. The Yin To ensure the good heat, motor shell motors surface should be maintained clean.
2, when the motor heat protection and short circuit protection continuously happen when, should find fault reasons and eliminate rear can put into operation.
3, motor bearing should maintain good lubrication. Y series motor bearing with grease for ZL - 3 lithium grease.
4 should be stored, motor inventory dry and clean, without acid in the environment of corrosive gas, etc.
5, our free to provide users with quality and bad for motor manufacturing fault "3 packets" maintenance service. Don't assume other incidental expenses.